Select the type of procedure
1
Enquiry period
with
02.10.2026 15:33
to 16.10.2026 12:00
to 16.10.2026 12:00
2
Bidding period
with
16.10.2026 12:00
to 27.10.2026 08:30
to 27.10.2026 08:30
4 days left
3
Auction
will not be used
4
Evaluation
5
Contract
Status
Bidding period
Estimated value without VAT
649 000 MDL
Period of clarifications:
2 Oct 2026, 15:33 - 16 Oct 2026, 12:00
Submission of proposals:
16 Oct 2026, 12:00 - 27 Oct 2026, 8:30
Supplier technical support:
(+373) 79999801
This procedure is carried out without auction. Your offer is final and must contain the entire list of required documents.
Subscribe impossible
during the period Bidding period
Traductoare de presiune absolută, diferențială
Information about customer
Title
Fiscal code/IDNO
Address
2049, MOLDOVA, mun.Chişinău, mun.Chişinău, sos. Balcani 7/E
Web site
---
The contact person
Purchase data
Date created
2 Oct 2026, 15:33
Date modified
8 Oct 2026, 14:03
Achizitii.md ID
21685745
MTender ID
CPV
38400000-9 - Instrumente de verificare a proprietăţilor fizice
Type of procedure
Low cost purchase
Award criteria
The lowest price
Funding sources
List of lots
Documents of the procurement procedure
Proiect contract Traductoare de presiune.pdf
Proiect contract Traductoare de presiune.pdf
Draft contract - special conditions
Proiect contract Traductoare de presiune
2.10.26 15:33
Anunț de participare nr.30 din 02.10.2026.signed.pdf
Anunț de participare nr.30 din 02.10.2026.signed.pdf
Bidding Documents
Anunț de participare nr.30 din 02.10.2026
2.10.26 15:33
Formulare la Anunț de participare nr.30 din 02.10.2026.docx
Bidding Documents
Formulare la Anunț de participare nr.30 din 02.10.2026
2.10.26 15:33
Specificație tehnică_Tratuctoare de presiune absoluta.docx.pdf
Specificație tehnică_Tratuctoare de presiune absoluta.docx.pdf
Technical Specifications
Specificație tehnică_Tratuctoare de presiune absoluta
2.10.26 15:33
Specificație tehnică_Tratuctoare de presiune diferențială.docx.pdf
Specificație tehnică_Tratuctoare de presiune diferențială.docx.pdf
Technical Specifications
Specificație tehnică_Tratuctoare de presiune diferențială
2.10.26 15:33
Date:
8 Oct 2026, 14:03
Question's name:
Flansa Coplanar
Question:
De ce solicitați conectarea Coplanar? Putem oferta o flanșă de montare tradițională (care este mai comună)? În plus, traductoarele de presiune sunt solicitate asamblate cu manifold. Prin urmare, vă rugăm să confirmați disponibilitatea atât a unei flanșe Coplanar, cât și a unei flanșe tradiționale. În caz contrar, concurența va fi limitată. Această specificație descrie doar tipul de conexiune de montare și nu afectează alte caracteristici ale dispozitivului.
Answer (9 Oct 2026, 13:12):
Da, la un traductor de presiune diferențială (DP) care este livrat asamblat direct cu un manifold, nu mai este necesară o flanșă Coplanar separată pentru conectarea manifoldului la traductor, dacă manifoldul este conceput pentru montaj direct pe conexiunile DP ale traductorului.
Date:
8 Oct 2026, 14:05
Question's name:
Temperatura mediu ambiant
Question:
Daca aveti situatii cu temperatura ambianta de -51 C sau +85 C? Daca nu exista, Va rugam sa corectati cu un diapazon real.
Answer (9 Oct 2026, 13:13):
Domeniu temperatură mediu ambiant −40…+85 °C
Date:
8 Oct 2026, 14:06
Question's name:
Temperatura mediu masurat
Question:
Daca sunt cazuri ca temperatura gazului este -73 C sau +205 C? Daca nu exista, Va rugam sa corectati cu un diapazon real.
Answer (9 Oct 2026, 13:14):
Domeniu temperatură mediu ambiant −40…+85 °C
Date:
8 Oct 2026, 14:08
Question's name:
Bloc supape presiunea diferentiala
Question:
Pentru senzori de presiunea diferentiala, Va rugam sa indicati tipul blocului de supape: cu 3 cai sau cu 5 cai?
Answer (9 Oct 2026, 13:15):
Bloc de supape cu cinci căi
Date:
8 Oct 2026, 14:10
Question's name:
Posibilitatea montare Rosemount 305
Question:
Cerinta de posibilitatea montare pe Rosemount 305 poate limita concurenta si favoriza producatorul anumit. Mai ales ca senzorii noi se solicita cu blocuri de supape noi. Va rugam sa excludeti cerinta respectiva.
Answer (9 Oct 2026, 13:15):
Ansamblul format din traductorul de presiune diferențială și manifoldul nou trebuie să fie compatibil cu infrastructura existentă de montare de tip Rosemount 305 și să permită instalarea pe poziția existentă, fără modificarea conductelor de impuls și a conexiunilor existente.
Date:
8 Oct 2026, 14:11
Question's name:
Clasa de presiune pentru senzorii de presiune diferentiala
Question:
Va rog sa indicati clasa de presiune solicitata pentru senzorii de presiune diferentiala. PN 160? PN 250? PN 420?
Answer (9 Oct 2026, 13:16):
Presiunea statică maximă de lucru/linia de proces PN100
Date:
8 Oct 2026, 15:08
Question's name:
Conectarea proces senzori presiunea absoluta
Question:
Va rugam sa specificati dimensiunea si tipul conexiunii de proces pentru senzori de presiune absoluta: filet G1/2 EN837, flansa DN 25, ect...?
Answer (9 Oct 2026, 13:16):
Conectare la proces pentru senzorii de presiune absolută: 1/2"–14 NPT, filet interior (Female).
Date:
8 Oct 2026, 15:18
Question's name:
Clasa senzori temperatura
Question:
Daca va fi considerat ca avantaj ofertarea senzorilor de temperatura clasa AA?
Answer (9 Oct 2026, 13:16):
Nu, ofertarea senzorilor de temperatură cu clasa de exactitate AA nu va constitui un avantaj și nu va fi evaluată suplimentar.
Date:
9 Oct 2026, 11:38
Question's name:
Cerinte metrologice
Question:
Va rugam sa clarificati cerintele metrologice. Ce document se accepta la primire:
1. Daca instrumentul e conform MID, se va accepta inscriptia M26 si certificat conformitate?
2. Daca instrumentul e fara MID, se va accepta calibrarea conform ISO17025 cu confirmarea documentului de la Institutul de Metrologie a Moldovei?
Answer (12 Oct 2026, 12:01):
În cazul traductoarelor conforme cu MID, se vor prezenta marcajele și documentele de evaluare a conformității prevăzute de legislația aplicabilă, cu condiția recunoașterii acestora pentru utilizarea instrumentului în Republica Moldova.
Date:
9 Oct 2026, 13:22
Question's name:
Posibilitatea montare Rosemount 305
Question:
La raspusnul respectiv: Ansamblul format din traductorul de presiune diferențială și manifoldul nou trebuie să fie compatibil cu infrastructura existentă de montare de tip Rosemount 305 și să permită instalarea pe poziția existentă, fără modificarea conductelor de impuls și a conexiunilor existente.
Intrebarea: daca putem vizita santierul pentru a clarifica subiectul de montare.
Answer (12 Oct 2026, 12:09):
Răspunsul complet pentru Clarificarea nr.9 de mai sus:
În cazul traductoarelor fără MID, certificatul de etalonare emis de un laborator acreditat conform SM EN ISO/IEC 17025 poate fi acceptat numai dacă instrumentul nu este supus controlului metrologic legal. Dacă traductorul este supus acestui control, se va prezenta documentul care atestă efectuarea verificării metrologice legale, conform cerințelor aplicabile.
Răspunsul pentru clarificarea nr.10/Vizita în teren:
Având în vedere că obiectivul este clasificat drept obiect industrial periculos și are importanță strategică, vizitarea amplasamentului se poate efectua numai cu respectarea procedurilor de acces și a cerințelor de securitate aplicabile. Clarificarea condițiilor de montare urmează să fie realizată, în primul rând, prin examinarea documentației tehnice prezentate. Dacă se va considera necesară vizitarea amplasamentului, aceasta va putea fi organizată după recepționarea solicitării oficiale, în urma examinării și aprobării acesteia de către beneficiar, cu respectarea procedurilor de acces și a cerințelor de securitate stabilite.
Date:
12 Oct 2026, 13:22
Question's name:
Posibilitatea montare Rosemount 305
Question:
Considerand raspunsurile de mai sus, Va rugam sa excludeti cerinta despre Rosemount 305, ca nu este relevanta. Traductorii noi vor fi livrate cu blocuri de supape noi.
Answer (12 Oct 2026, 16:33):
Răspunsul la prezenta solicitare de clarificări a fost oferit în cadrul clarificărilor anterioare.
Date:
12 Oct 2026, 13:28
Question's name:
Conformitate MID
Question:
La raspuns: În cazul traductoarelor conforme cu MID, se vor prezenta marcajele și documentele de evaluare a conformității prevăzute de legislația aplicabilă, cu condiția recunoașterii acestora pentru utilizarea instrumentului în Republica Moldova.
Intrebarea: In cazul respectiv, aprobarea MID nu necesita recunoasterea RM (conform HG 408, Legii 235). Asadar, Va rugam sa confirmati ca veti receptiona instrumentele cu marcaj MID fara solicitarea altor documente.
Ca la moment, nu este clar raspunsul.
Answer (12 Oct 2026, 16:34):
Răspunsul la prezenta solicitare de clarificări a fost oferit în cadrul clarificărilor anterioare.
Only authorized platform users may ask questions during the clarification period.
Document successfully signed
OK