1
Enquiry period
with 20.04.2022 11:37
to 18.05.2022 13:48
2
Bidding period
with 18.05.2022 13:48
to 25.05.2022 13:48
3
Auction
will not be used
4
Evaluation

5
Contract

Status Evaluation
Estimated value without VAT 3 963 595 MDL
Period of clarifications: 20 Apr 2022, 11:37 - 18 May 2022, 13:48
Submission of proposals: 18 May 2022, 13:48 - 25 May 2022, 13:48

Supplier technical support:

(+373) 79999801


This procedure is carried out without auction. Your offer is final and must contain the entire list of required documents.

Lucrări de reparații curente la Agenția Medicamentului și Dispozitivelor Medicale din str. Korolenko 2/1, mun. Chișinău
Information about customer
Fiscal code/IDNO
Address
MD-2028, MOLDOVA, mun.Chişinău, mun.Chişinău, str. Korolenko 2/1
Web site
---
The contact person
Full name
Tatiana Aramă
Contact phone
068238258
Purchase data
Date created
20 Apr 2022, 11:37
Date modified
29 Apr 2022, 13:18
Achizitii.md ID
21055362
CPV
45400000-1 - Lucrări de finisare a construcţiilor
Type of procedure
Open tender
Award criteria
The lowest price
Funding sources
Documents of the procurement procedure
documentatia standard lucrări.docx
Bidding Documents
-
20.04.22 11:37
2 duae.doc
Bidding Documents
-
20.04.22 11:37
Date:
29 Apr 2022, 13:18
Question's name:
Deviz iluminat electric
Question:
Pozitia 62 Jgeab neperforat din PVC 100x60mm, inclusiv capacul p/u jgeab. LEGRAND sau analog ce norma ????????
Answer (3 May 2022, 16:40):
Pozitia 62 Jgeab neperforat din PVC 100x60mm, inclusiv capacul p/u jgeab. LEGRAND sau analog, norma este de 100m/100m.
Date:
29 Apr 2022, 15:24
Question's name:
Reparatii Bloc C
Question:
Capitol 3.3 Terasa. Pereti (Soclu) p,26 CF15A Pentru utilizarea mortarului marfa M-100T fara ciment pentru grund SE EXCLUDE CIMENTUL ?????? SI LASAM MORTARUL 100-T ?
Answer (3 May 2022, 16:41):
Capitol 3.3 Terasa. Pereti (Soclu) p.26 CF15A Pentru utilizarea mortarului marfa M-100T fara ciment pentru grund, CIMENTUL nu se exclude, MORTARUL 100-T este doar pentru informatie.
Date:
3 May 2022, 09:59
Question's name:
Reparatia Bloc C
Question:
Pozitia 54 Pavaj gr.4 cm, specificati ce fel de pavaj ? Bobina ???? sau de care este nevoie
Answer (4 May 2022, 18:54):
pozitia 54 - pavaj gr.4 cm de tip caramida cu dimensiunile 20 x 10 cm
Date:
3 May 2022, 10:54
Question's name:
Reparatie bloc C
Question:
Pozitia 55, Specificati grosimea la invelitorile din placi de policarbonat ???? Celular ? sau solid ???
Answer (4 May 2022, 18:54):
Pozitia 55 placi de policarbonat celular gr. 4mm.
Date:
5 May 2022, 08:55
Question's name:
Bloc C
Question:
Pozitia 20 Sika Last-1K, consum 3kg/m2 este materialul cu care se hidroizoleaza ? Excludem mortarul gata prefabricat ?
Answer (6 May 2022, 10:40):
Pozitia 20 se hidroizoleaza cu Sika Last-1K, iar mortarul se exclude.
Date:
5 May 2022, 10:56
Question's name:
Bloc B
Question:
Deviz Ventilare (VC) Pozitiile 8,9,10,11, nu sunt normele la urmatoarele resurse: Dispozitiv-clapeta 0,00; Fixari 0,00; Plase in rame 0,00; Suber (registru) 0,00; Capac hidrometric 0,00. Specificare care sunt normele ?????
Answer (6 May 2022, 10:40):
Deviz Ventilare, pozitiile 8,9,10,11 normele la resursele cu norma 0,00 se exclud.
Date:
6 May 2022, 17:37
Question's name:
Caiet de sarcini
Question:
Buna ziua La pozitia Ventilare (IVC) poz. 17 Clapeta cu contragreutate, cu perimetrul 800 - 1600 mm, confectionate in ateliere centralizate. (Clapeta de aer D=150mm S=0.7mm Moven) P150P - doar montarea unde este indicat doar montarea care pozitii trebuie de sters, cum procedam corect?
Answer (10 May 2022, 12:13):
La compartimentul Ventilare (IVC) Bloc B, poz.17,19,21,23,25,27,35,37 unde este indicata doar montarea, se lasa materialele necesare montarii utilajului indicat conform pozitiei.
Date:
6 May 2022, 17:48
Question's name:
Solutii arhitectural-constructive (SAC)
Question:
Bună ziua poziția 13 Reparatii de tencuieli interioare, in fisii de 10-20 cm latime, la imbinarea dintre panourile mari din beton armat si la racordul peretilor cu plinte etc., avind grosimea de 0,5 cm, aplicate in 2 straturi cu mortar M 100, (grund si stratul vizibil). (Rostul intre perete si terasa se sigileaza cu banda elastica Sika Seal Tape-S, se lipeste cu SikaLasctic-1K, consum=1,5kg/m.l) spunetine va rog ce pozitie trebuie sa adaugam banda elastica Sika Seal Tape-S si SikaLasctic-1K daca da care este norma de consum la ambele?
Answer (10 May 2022, 12:14):
La compartimentul Solutii arhitectural-constructive (SAC) Terasa, poz.13, se adauga banda elastica Sika Seal Tape-S (norma de consum 1.05m.l.) si SikaLasctic-1K (norma de consum 1,5kg/m.l).
Date:
6 May 2022, 17:53
Question's name:
Bloc B
Question:
Buna ziua Deviz Ventilare (IVC) Pozitia 3.9 Filtru de aer pentru conditionare, K1-K25’’ – 20buc. Puteti preciza tipurile / modelele / marcile conditionerelor pentru a stabili tipul filtrelor de care este nevoie?
Answer (10 May 2022, 12:15):
La compartimentul Ventilare (IVC) Bloc B, poz.3.9 Filtru de aer pentru conditioner, K1-K25, este necesar de vizitat obiectul pentru a vedea tipurile de conditionere.
Date:
11 May 2022, 11:32
Question's name:
Obiectivul: Reparație curentă a încăperilor blocului administrativ "Bloc B" din mun. Chișinău, str. Korolenco 2/1 Obiectul: Retele interioare de alimentare cu apa si canalizare (RAC)
Question:
IzA06D Vopsitorii anticorozive pe timplarie metalica, utilaje tehnologice si constructii metalice cu email alchidic (un strat grund de miniu si trei straturi de email).
Answer (11 May 2022, 13:43):
Care este întrebarea?
Date:
11 May 2022, 11:35
Question's name:
Obiectivul: Reparație curentă a încăperilor blocului administrativ "Bloc B" din mun. Chișinău, str. Korolenco 2/1 Obiectul: Retele interioare de alimentare cu apa si canalizare (RAC)
Question:
IzA06D Vopsitorii anticorozive pe timplarie metalica, utilaje tehnologice si constructii metalice cu email alchidic (un strat grund de miniu si trei straturi de email -ce consum pentru email ar trebui un un k de aplicat daca sunt 3 straturi consumul e mic ?
Answer (12 May 2022, 12:42):
De executat ofeta conform caietului de sarcini.
Date:
13 May 2022, 10:02
Question's name:
SAC
Question:
Pozitia 12 CF17D este aplicativa va rugam sa ne descifrati receta normei se adauga ceva?
Answer (13 May 2022, 13:58):
SAC, Pozitia 12 CF17D - receta nu se schimba
Date:
13 May 2022, 10:38
Question's name:
Bloc B Ventilare (VC)
Question:
Lucrari de montare Pozitiile 1,2,3 nu sunt normele la urmatoarele resurse: Agregat de climatizare AMC 1-6, Ventilator radial silentios , le excludem ?
Answer (13 May 2022, 13:59):
Bloc B Ventilare (IVC), Lucrari de montare Pozitiile 1,2,3 - resurse: Agregat de climatizare AMC 1-6 si Ventilator radial silentios se exclud
Date:
13 May 2022, 17:45
Question's name:
Reparatia curenta a demisolului (terasa) "Bloc C
Question:
Poz nr. 21 CG47C ad - Pardoseli din placi de gresie ceramica, inclusiv stratul suport din adezivi (Sikaceram-225 consum 6 kg/mp). Se utilizeaza in loc de "Adeziv pentru lucrari de placaj (amestc uscat)" - "Sikaceram - 225" si se modifica norma de consum din 4.7kg in 6.0 kg? Corect am inteles?
Answer (16 May 2022, 13:48):
Corect. Se utilizeaza in loc de Adeziv pentru lucrari de placaj (amestc uscat)-Sikaceram - 225 si se modifica norma de consum din 4.7kg in 6.0 kg.
Date:
16 May 2022, 13:58
Question's name:
Incalzire Bloc B Lucrari de constructie
Question:
Poz 120 08-02-390-3 Canal tip PPR consolidat, H=80mm ce norma de consum ?
Answer (16 May 2022, 16:39):
Poz 120 08-02-390-3 Canal tip PPR consolidat, H=80mm - are norma de consum 100m/100m
Date:
17 May 2022, 15:30
Question's name:
Incalzire Bloc B Lucrari de montare
Question:
Poz 2.1-2.7 contin si materialul care se regaseste la utilaj , excludem robinetii si colectorul ?
Answer (18 May 2022, 13:30):
Da, excludem robinetii si colectorul.
Only authorized platform users may ask questions during the clarification period.