1
Enquiry period
with 19.06.2019 12:22
to 24.06.2019 10:00
2
Bidding period
with 24.06.2019 10:00
to 27.06.2019 12:00
3
Auction
with 28.06.2019 15:00
to 28.06.2019 15:14
4
Evaluation

5
Contract

Status Evaluation
Estimated value without VAT 250 000 MDL
Period of clarifications: 19 Jun 2019, 12:22 - 24 Jun 2019, 10:00
Submission of proposals: 24 Jun 2019, 10:00 - 27 Jun 2019, 12:00

Supplier technical support:

(+373) 79999801

UPS trifazat de tip On-line pentru secția Medicina Nucleară

Information about customer
Fiscal code/IDNO
Address
MD-2025, MOLDOVA, mun.Chişinău, mun.Chişinău, str. N. Testemiteanu 29
Web site
---
The contact person
Full name
Milena Prutean
Contact phone
22403697
Purchase data
Date created
19 Jun 2019, 12:22
Date modified
20 Jun 2019, 11:18
Achizitii.md ID
21009226
CPV
31600000-2 - Echipament electric
Type of procedure
Procedură de valoare mică (goods)
Award criteria
The lowest price
Funding sources
List of lots
Documents of the procurement procedure
documentatia_standard_ups.semnat.pdf documentatia_standard_ups.semnat.pdf
Bidding Documents
documentatia_standard
19.06.19 12:22
oferta_ups.xlsx
Bidding Documents
oferta
19.06.19 12:22
duae_ups.semnat.pdf duae_ups.semnat.pdf
Eligibility Criteria
duae
19.06.19 12:22
duae_ups.doc
Eligibility Criteria
duae
19.06.19 12:22
anunt de participare-ups.semnat.pdf anunt de participare-ups.semnat.pdf
tenderNotice
anunt de participare
19.06.19 13:07
Lot 1 UPS trifazat de tip On-line
Date:
20 Jun 2019, 11:18
Question's name:
precizari
Question:
În Cerințe este stipulat timpul de lucru mai mare de 10 minute . Ok. Precizați Vă rog - la ce sarcină ?....de obicei se cere timp de ...(în cazul nostru 10 min) în decurs de 70....80....90...100%. Mulțumesc anticipat
Answer (20 Jun 2019, 13:29):
Bună ziua, Timpul de lucru necesar mai mult de 10 min la sarcina de 50% dar nu mai putin de 5 min la 100%. Vă mulțumim!
Lot 1 UPS trifazat de tip On-line
Date:
21 Jun 2019, 12:18
Question's name:
Sarcina electrica a UPS-ului
Question:
1) Specificati sarcina electrica - IT, general, sala operatie , Computer Tomograf, Angiograf , etc ? 2) Exista curent de shoc in sarcina? 3) Daca exista - care e valoarea curentului de shoc si durata ?
Answer (21 Jun 2019, 14:41):
Sarcina electrica este un tomograf computerizat. Nu exista curent de soc in sarcina.
Lot 1 UPS trifazat de tip On-line
Date:
21 Jun 2019, 12:30
Question's name:
Opțiuni
Question:
"Opțiuni: Bypass. Transformator de izolație." Optiunile mentionate necesar de inclus in configuratia UPS (si de specificat costul) sau de a confirma posibilitatea dotarii UPSului ulterior cu aceste optiuni?
Answer (21 Jun 2019, 14:41):
Optiunile de Bypass si Transformator de izolatie sunt necesare de a fi incluse in configuratia propusa.
Date:
21 Jun 2019, 16:55
Question's name:
Bypass si altele
Question:
1) Concretizati Va rog tipul de by-pass solicitat - intern de mentenanta (in interioru UPS) sau extern de mentenanta (in panou separat)? 2) Transformator de izolatie galvanica urmeaza sa fie conectat la linia de: intrare, iesire sau by-pass ? 3) Ar fi de dorit de inclus in configuratia UPSului card dry-contact pentru functia EPO ( Emergency Power Off\ oprire de urgenta UPS de la distanta) ? 4) Ar fi de dorit de inclus in configuratia UPSului card de monitorizare UPS de la distanta ( protocol SNMP )?
Answer (24 Jun 2019, 08:15):
Bypass intern. Transformator la întrare. Mai multe optii nu e necesar
Only authorized platform users may ask questions during the clarification period.